      CVM-C10-ITF-485-ICT2

      CVM-C10-ITF-485-ICT2, Power analyzer

      Code: M55911.

      • ?Protocol: Modbus/RTU | BACnet
      • ?Communications: RS-485
      • ?Transistor output: 2
      • ?No relays: 2
      • ?Digital inputs: 2
      • ?Measuring current Channels: 3
      • ?Harmonics: 31
      • ?Input current: .../5 A | .../1 A
      • ?Mounting: Pannel
      • ?Modules: 96 x 96



      DESCRIPTION

      The?CVM-C10?is a panel mounted (96 x 96 mm) power analyzer that records energy values. Compact and versatile, with 4-quadrant measurement (consumption and generation). Suitable for Medium or Low voltage installations, in both 3 or 4-wire three-phase circuits,
      two-phase circuits with or without neutral, single-phase circuits or ARON connections.

      Display features and interface:

      • Backlit touch-screen (capacitive)
      • Analogue display of instantaneous parameters (power, maximum power reached and cos φ or PF)
      • Backlit display
      • Alarm LED indicator.
      • Tariff cost
      • Operating hour indicator for preventive maintenance
      APPLICATIONS
      • Record the energy consumption from three different sources: network, generator set or photovoltaic energy generation system.
      • Generation of an impulse signal associated with the cost, kgCO2?emissions or savings, according to the consumption or generation of energy.
      • Selection of tariffs with digital inputs. Perfect to calculate costs in three different work shifts.
      • Programs alarms on any instantaneous parameter measured or calculated. Configurable parameters: Low/High, hysteresis (%), NO/NC,
        connection/disconnection delay and interlocking.
      AC POWER SUPPLY
      Installation category
      CAT III 300 V
      Consumption
      4 ... 6 VA
      Frequency
      50 ... 60 Hz
      Nominal voltage
      95 ... 240 V ~ ± 10%
      DC POWER SUPPLY
      Installation category
      CAT III 300 V
      Consumption
      2 ... 6 W
      Nominal voltage
      105 ... 272 Vdc ± 10%
      MECHANICAL CHARACTERISTICS
      Size (mm) width x height x depth
      96 x 96 x 60.9 (mm)
      Envelope
      Self-extinguishing V0 plastic
      Fastening
      Panel
      Weight (kg)
      0,314
      ENVIRONMENTAL CHARACTERISTICS
      Protection class
      IP 51 (Front), IP 64 (with accessory), IP 21 (rear)
      Relative humidity (without condensation)
      5 ... 95%
      Storage temperature
      -10… +65 oC
      Operating temperature
      -10 …+60 oC
      STANDARDS
      Certifications
      UL/CSA 61010-1 3rd edition, UL, VDE
      Electrical safety, Maximum height (m)
      2000
      Standards
      UNE EN 61010, UNE EN 61000-6-3, UNE EN 61000-6-1, IEC 664, VDE 0110, UL 94, BS EN 61000-6-2, BS EN 61000-6-4
      CURRENT MEASUREMENT CIRCUIT
      Installation category
      CAT III 300 V
      Nominal current (In)
      .../5A , .../1 A
      Phase current measuring range
      2 ... 120% In
      Maximum input current consumption
      0,9VA
      Maximum pulse current
      100 A
      Minimum current measurement
      10 mA
      VOLTAGE MEASUREMENT CIRCUIT
      Installation category
      CAT III 300 V
      Input impedance
      440 kΩ
      Frequency measuring range
      45 ... 65 Hz
      Voltage measuring range
      5 ...120% Un
      Nominal voltage
      300V Ph-N, 520V Ph-Ph
      Minimum measurement voltage (Vstart)
      15 V
      COMMUNICATIONS
      Fieldbus (BACnet)
      MS/TP
      Fieldbus (ModBus)
      RS-485 / RTU
      Stop bits (BACnet)
      1
      Stop bits (ModBus)
      1-2
      Parity (BACnet)
      non
      Parity
      non-pair-impar
      Protocol
      ModBus/BACnet
      Speed
      9600-19200
      USER INTERFACE
      LED
      3 LED
      Keyboard
      Capacitive, 3 keys
      Display type
      LCD Custom COG
      DIGITAL INPUTS
      Input/output insulation
      Optoisolated
      Quantity
      2
      Type
      NPN Potential-free contact
      DIGITAL RELAY OUTPUTS
      Electrical life (at maximum load)
      60x103?cycles
      Mechanical life
      10x106?cycles
      Maximum switching capacity
      1500 VA
      DIGITAL TRANSISTOR OUTPUTS
      Pulse width
      30 ms a 500 ms (Programmable)
      Quantity
      2
      Type
      NPN salida
      Maximum frequency
      16 imp / s
      Maximum current
      50 mA
      Maximum voltage
      24 Vdc